01
Systematic review and meta-analysis · 25 studies (17 randomized clinical trials)
Most effective method for the management of physiologic gingival hyperpigmentation: A systematic review and meta-analysis
Gul M, Hameed MH, Nazeer MR, Ghafoor R, Khan FR · Journal of Indian Society of Periodontology 23(3):203-215, 2019 · PMID 31143000 · DOI 10.4103/jisp.jisp_555_18
In the meta-analysis comparing laser and scalpel (surgical stripping), there was no difference in recurrence (P=0.75) or depigmentation (P=0.23), and pain after the procedure was lower with the laser (P≤0.05). It also summarized the result that re-pigmentation was more frequent with the laser in the 6-month assessment.
LimitationsThe quality of the included studies was uneven, and the authors considered that better randomized trials are needed.
02
Randomized controlled clinical study · 24 patients
Assessment of clinical outcomes and patient response to gingival depigmentation using a scalpel, ceramic bur, and diode laser 980 nm
Mikhail FF, El Menoufy H, El Kilani NS · Clinical Oral Investigations 27(11):6939-6950, 2023 · PMID 37878070 · DOI 10.1007/s00784-023-05310-w
In all three groups (scalpel, ceramic bur and diode laser), the pigmentation index decreased compared with before the procedure, with no difference between the groups. Pain 12 hours after the procedure was lower in the laser group than in the scalpel group (p=0.003).
LimitationsThere were only 24 participants.
03
Randomized clinical trial (2-year follow-up) · 60 patients
Gingival depigmentation with diode and Er,Cr:YSGG laser: evaluating re-pigmentation rate and patient perceptions
Altayeb W, Hamadah O, Alhaffar BA, Abdullah A, Romanos G · Clinical Oral Investigations 25(9):5351-5361, 2021 · PMID 33624200 · DOI 10.1007/s00784-021-03843-6
In both the diode laser (940 nm) and Er,Cr:YSGG laser groups, the pigmentation index was lower than before the procedure at 1 month, 1 year and 2 years. The extent of re-pigmentation at 1 year and 2 years was greater in the Er,Cr:YSGG group (p<0.05).
LimitationsOnly the outer side of the upper gums was studied.
04
Systematic review (Poisson regression analysis) · 61 papers (mostly case reports)
Systematic review of treatment modalities for gingival depigmentation: a random-effects poisson regression analysis
Lin YH, Tu YK, Lu CT, et al. · Journal of Esthetic and Restorative Dentistry 26(3):162-178, 2014 · PMID 24418367 · DOI 10.1111/jerd.12087
The repigmentation incidence estimated with a statistical model that accounts for follow-up time (Poisson regression) was 0.32% for cryosurgery, 0.74% for electrosurgery, 1.16% for laser, and 8.89% for bur abrasion. Because it is an incidence that accounts for time, it differs from a cumulative rate such as the percentage of treated people whose pigmentation came back.
LimitationsBecause this analysis mostly pools case reports, it has major limitations as a comparison between methods.