01
Controlled clinical trial · 140 sites
Comparison of surgical stripping; erbium-doped:yttrium, aluminum, and garnet laser; and carbon dioxide laser techniques for gingival depigmentation: a clinical and histologic study
Hegde R, Padhye A, Sumanth S, et al. · Journal of Periodontology 84(6):738-48, 2013 · PMID 23003920 · DOI 10.1902/jop.2012.120094
Repigmentation seen by eye at 6 months appeared in 21.4% (15/70) of sites for the scalpel, 28.6% (10/35) for the Er:YAG laser, and 22.8% (8/35) for the CO2 laser.
LimitationsPatients were followed only up to 6 months.
02
Randomized clinical trial (2 years)
Gingival depigmentation with diode and Er,Cr:YSGG laser: evaluating re-pigmentation rate and patient perceptions
Altayeb W, Hamadah O, Alhaffar BA, Abdullah A, Romanos G · Clinical Oral Investigations 25(9):5351-5361, 2021 · PMID 33624200 · DOI 10.1007/s00784-021-03843-6
Both the diode (940 nm) and Er,Cr:YSGG (2780 nm) lasers reduced pigmentation, and the degree and extent of repigmentation at 1 and 2 years were significantly greater with the Er,Cr:YSGG laser.
LimitationsOnly two types of laser were compared.
03
Systematic review and meta-analysis · 25 studies
Most effective method for the management of physiologic gingival hyperpigmentation: A systematic review and meta-analysis
Gul M, Hameed MH, Nazeer MR, Ghafoor R, Khan FR · Journal of Indian Society of Periodontology 23(3):203-215, 2019 · PMID 31143000 · DOI 10.4103/jisp.jisp_555_18
Repigmentation did not differ between laser and scalpel (P=0.75), but at the 6-month assessment, repigmentation was higher with the laser.
LimitationsIt concluded that higher-quality randomized studies are needed.
04
Systematic review · 61 studies (mostly case reports)
Systematic review of treatment modalities for gingival depigmentation: a random-effects poisson regression analysis
Lin YH, Tu YK, Lu CT, et al. · Journal of Esthetic and Restorative Dentistry 26(3):162-178, 2014 · PMID 24418367 · DOI 10.1111/jerd.12087
The repigmentation incidence estimated by accounting for follow-up time was 0.32% for cryosurgery, 0.74% for electrosurgery, 1.16% for laser, and 8.89% for bur abrasion. This is not a cumulative recurrence rate.
LimitationsIt mainly pooled case reports.
05
Clinical study (18 months)
Comparison of recurrent rate of gingival pigmentation after treatment by liquid nitrogen and cryoprob in 18 months follows-up
Sedeh SA, Badihi S, Esfahaniyan V · Dental Research Journal 11(5):592-8, 2014 · PMID 25426152
Neither of the two cryosurgery methods showed significant repigmentation over 18 months.
LimitationsOnly cryosurgery methods were compared with each other.
06
Meta-analysis · 13 randomized clinical trials · 233 patients
Effect of diode laser on oral pigmentation, pain, and wound healing in patients with gingival hyperpigmentation: a meta-analysis
Zheng W, Pang Y, Gong H, et al. · Quintessence International (Berlin, Germany 55(9):692-702, 2024 · PMID 39162208 · DOI 10.3290/j.qi.b5695436
The diode laser had lower pigmentation scores than other methods (standardized mean difference −0.245) and also caused less pain (−0.809). The authors concluded that the diode laser lengthens the time until repigmentation.
LimitationsPublication bias was suspected in the pain results.