Skip to main content

Paper Q&ADental ImplantComparison and Choice

Can it be done with short implants instead of a bone graft?

In a meta-analysis of 8 randomized clinical trials on the thin-boned upper back tooth area, there was no difference in failure rate between short implants of 8 mm or less and standard-length implants after a sinus lift (risk ratio 1.05, 95% confidence interval 0.68–1.75, heterogeneity 0%), and surrounding bone loss was 0.15 mm lower with short implants.

An umbrella review pooling several meta-analyses contained both a result that short implants (under 10 mm) have a higher failure risk than long implants (moderate certainty) and a result that long implants after bone grafting have a higher failure risk than short implants (high certainty). Which method is right depends on the remaining bone height.

Evidence cards
Paper 3 (Systematic review and meta-analysis 3)
Cited Papers
Paper 3 · Latest, 2026
Literature Review Date
2026.10.22

Evidence for This Question

Systematic review and meta-analysis · 8 randomized clinical trials

Short implants (≤ 8 mm) versus standard implants with sinus floor elevation in the atrophic posterior maxilla: A systematic review and meta-analysis of randomized controlled trials

Wang C, Xin C, Zhang N, Li L · Journal of Stomatology, Oral and Maxillofacial Surgery 127(5):102913, 2026 · PMID 42520929 · DOI 10.1016/j.jormas.2026.102913

There was no difference in failure rate between short implants of 8 mm or less and standard implants after a sinus lift (risk ratio 1.05, 95% confidence interval 0.68–1.75, P=0.83, I²=0%), and surrounding bone loss was 0.15 mm lower with short implants.

LimitationsIt covered only the upper back tooth area.

Umbrella review · 25 meta-analyses · 35 associations

Factors leading to implant failure: An umbrella review of meta-analyses of observational studies and trials

Giok KC, Veettil SK, Wei CX, Menon RK · The Journal of Prosthetic Dentistry 135(3):518-527, 2026 · PMID 40425441 · DOI 10.1016/j.prosdent.2025.04.041

Long implants after bone grafting had a higher failure risk than short implants (high certainty), and short implants (under 10 mm) had a higher failure risk than long implants (moderate certainty).

LimitationsThe conditions compared differ, so the two results are hard to set against each other directly.

Meta-analysis · 27 studies

What Affects Postoperative Sinusitis and Implant Failure after Dental Implant: A Meta-analysis

Kim JS, Choi SM, Yoon JH, et al. · Otolaryngology--head and Neck Surgery 160(6):974-984, 2019 · PMID 30776960 · DOI 10.1177/0194599819829747

The factors that influenced failure in implants accompanied by sinus surgery were smoking and the remaining bone height of the upper jaw.

LimitationsMany observational studies were included.

Studies at a glance

StudyDesignParticipantsMain results
Wang C 2026Systematic review and meta-analysis8 randomized clinical trialsThere was no difference in failure rate between short implants of 8 mm or less and standard implants after a sinus lift (risk ratio 1.05, 95% confidence interval 0.68–1.75, P=0.83, I²=0%), and surrounding bone loss was 0.15 mm lower with short implants.
Giok KC 2026Umbrella review25 meta-analyses · 35 associationsLong implants after bone grafting had a higher failure risk than short implants (high certainty), and short implants (under 10 mm) had a higher failure risk than long implants (moderate certainty).
Kim JS 2019Meta-analysis27 studiesThe factors that influenced failure in implants accompanied by sinus surgery were smoking and the remaining bone height of the upper jaw.

Learn More

What is the standard for a short implant?

It differs from study to study. Card 01 considered 8 mm or less to be short, and one comparison in Card 02 considered under 10 mm to be short.

Why do the two results differ?

Card 01 compared «short implants» with «long implants after a sinus lift» in upper back teeth with lacking bone. The comparison of 「short vs. long implants」 in Card 02 includes situations where bone grafting is not needed, so the conditions differ.

Please check these together.

  • The remaining bone height and the condition of the maxillary sinus are checked with CT.
  • Tell us at the examination whether you smoke.

Frequently Asked Questions

References

  1. Wang C, Xin C, Zhang N, Li L. Short implants (≤ 8 mm) versus standard implants with sinus floor elevation in the atrophic posterior maxilla: A systematic review and meta-analysis of randomized controlled trials. J Stomatol Oral Maxillofac Surg. 2026;127(5):102913. PMID 42520929 · DOI 10.1016/j.jormas.2026.102913
  2. Giok KC, Veettil SK, Wei CX, Menon RK. Factors leading to implant failure: An umbrella review of meta-analyses of observational studies and trials. J Prosthet Dent. 2026;135(3):518-527. PMID 40425441 · DOI 10.1016/j.prosdent.2025.04.041
  3. Kim JS, Choi SM, Yoon JH, et al.. What Affects Postoperative Sinusitis and Implant Failure after Dental Implant: A Meta-analysis. Otolaryngol Head Neck Surg. 2019;160(6):974-984. PMID 30776960 · DOI 10.1177/0194599819829747

New York Yonsei Dental Clinic Treatment Guide

New York Yonsei Dental Clinic checks the amount and position of bone with panoramic X-rays, dental three-dimensional CT (CBCT) and an oral examination to decide on the implant treatment method.

Dental Implant Treatment Guide

This content is health information based on Korean and international academic papers and does not guarantee the result of any treatment. The figures cited are the results of the studies concerned, not the treatment outcomes of New York Yonsei Dental Clinic. Treatment effects and the right treatment differ from person to person, so please decide after an accurate diagnosis and consultation.

WhatsApp
Quick Consultation